Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.262
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597297

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Asunto(s)
Cateterismo Cardíaco , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Medición de Riesgo , Adolescente , Resultado del Tratamiento , Factores de Riesgo , Masculino , Niño , Estudios Retrospectivos , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Adulto Joven , Valor Predictivo de las Pruebas , Hemodinámica , Stents , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Toma de Decisiones Clínicas , Adulto
2.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38569760

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adulto , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Sistema de Registros , Diseño de Prótesis , Estudios Retrospectivos
4.
Artículo en Inglés | MEDLINE | ID: mdl-38522870

RESUMEN

Half a century after the first pulmonary autograft operation (Ross operation), performed in 1967 by Donald Ross in central London, there is a very strong conviction that the Ross operation is the best available valve substitute today, not only for children, but also for younger and older adults. The Ross operation has stimulated a lot of science to do with tissue-engineering and biology of heart valves, which is a promising avenue for the future. For one of us (M.Y.), it has certainly been a privilege to be associated with the comeback of the Ross operation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Niño , Humanos , Anciano , Autoinjertos/cirugía , Válvula Pulmonar/cirugía , Trasplante Autólogo , Reoperación , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
5.
Artículo en Inglés | MEDLINE | ID: mdl-38522871

RESUMEN

While it is the main viable option in the growing child and young adult, the Ross procedure has expanded its applicability to older patients, for whom long-term results are equivalent, if not superior, to prosthetic aortic valve replacement. Strategies aiming at mitigating long-term autograft failure from root enlargement and valve regurgitation have led some to advocate for root reinforcement with prosthetic graft material. On the contrary, we will discuss herein the rationale for a tailored approach to the Ross procedure; this strategy is aimed at maintaining the natural physiology and interplay between the various autograft components. Several technical maneuvers, including careful matching of aortic and autograft annuli and sino-tubular junction as well as external support by autologous aortic tissue maintain these physiologic relationships and the viability of the autograft, and could translate in a lower need for late reintervention because of dilation and/or valve regurgitation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Válvula Pulmonar , Niño , Adulto Joven , Humanos , Autoinjertos , Insuficiencia de la Válvula Aórtica/cirugía , Dilatación/efectos adversos , Trasplante Autólogo/efectos adversos , Trasplante Autólogo/métodos , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Reoperación , Válvula Pulmonar/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
6.
Artículo en Inglés | MEDLINE | ID: mdl-38522872

RESUMEN

The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (P = 0.002), aortic sinus diameter (P = 0.001) change in left ventricular function (P = 0.039) and change in aortic insufficiency (P = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Pulmonar , Niño , Humanos , Autoinjertos , Estudios Retrospectivos , Dilatación , Trasplante Autólogo , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Dilatación Patológica , Válvula Pulmonar/cirugía , Estudios de Seguimiento
7.
Catheter Cardiovasc Interv ; 103(4): 597-606, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38440908

RESUMEN

BACKGROUND: Current heart valve implants entail major disadvantages in the treatment for younger patients or those with congenital heart defects. AIM: Evaluation of novel transcatheter pulmonary valve implant made from autologous pericardium with natural crosslinking agent in an in vitro setup and in vivo animal model METHODS: Valves were tested in a pulse duplicator according to ISO-standard 5840. For in vivo studies computer tomography was performed to measure sheep's native pulmonary valve dimensions. Pericardium was harvested by thoracotomy, personalized implants were manufactured and deployed in pulmonary valve position of the same sheep. Every 3 months implant functionality was evaluated by intracardiac echocardiography, intracardiac pressure measurements and cardiac magnetic resonance imaging (cMRI). Implants were explanted for macroscopic and histological examination. RESULTS: In vitro experiments showed compliance with regulatory requirements in terms of valve opening and insufficiency. Five sheep successfully received an autologous valve implant. Two animals had to be euthanized due to trauma sustained in the stable. Long-term valve function was excellent in three out of four animals with median implant cMRI regurgitation fraction of 9% (n = 4) at 3 months, 8% (n = 3) at 6, 8% (n = 3) at 9, 12% (n = 3) at 13, 8% (n = 2) at 17% and 8% (n = 2) at 20.5 months after implantation. Despite good adherence to neighboring tissue and endothelization, histological assessment revealed some signs of degeneration. CONCLUSION: Transcatheter pulmonary valve implants showed promising function for up to 20.5 months encouraging research to further improve this approach.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Humanos , Adulto , Animales , Ovinos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Válvulas Cardíacas/cirugía , Modelos Animales
8.
Arch Cardiol Mex ; 94(1): 7-14, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38507314

RESUMEN

BACKGROUND: Congenital heart disease poses a therapeutic challenge, specifically pulmonary valve stenosis. This has been treated for many years with invasive procedures and bioprostheses, which over time, become dysfunctional due to the accumulation of fibrous tissue and calcification. OBJECTIVE: The aim of this study is to describe the use of endovascular management in the right ventricular outflow tract, as the beginning of an ongoing effot to improve pediatric outcomes in developing countries. METHODS: Seven pediatric patients with endovascular management of the right outflow tract are presented. Three of them underwent surgical valvuloplasty with persistent pulmonary stenosis. They decided to insert a percutaneous transcatheter pulmonary valve (PPVI) with a Melody valve using the valve-in-valve technique, with 100% stenosis and no complications associated with the procedure. RESULTS: Four patients with successful percutaneous valve implantation had different congenital heart diseases. In addition, the case of a patient in whom an intentional pulmonary valve fracture was performed, an innovative procedure in pediatric endovascular management in the country, is highlighted. CONCLUSIONS: The procedure was minimally invasive, safe, and effective. The IVPP technique could be a viable option in our country for managing failed primary valve implantations or even in native tracts.


ANTECEDENTES: Las cardiopatías congénitas plantean un desafío terapéutico, específicamente la estenosis de la válvula pulmonar. Esta ha sido tratada durante muchos años con procedimientos invasivos e inserción de bioprótesis, que con el tiempo se vuelven disfuncionales y pueden reestenosarse por acumulación de tejido fibroso y calcificación. Debido a las complicaciones generadas por la injuria quirúrgica, se han descrito medidas menos invasivas para el manejo de la estenosis residual e inicial por medios endovasculares en adultos y más recientemente en población pediátrica. OBJETIVO: El objetivo de este reporte es describir la misma en el manejo endovascular del tracto de salida del ventrículo derecho, como el inicio de un trabajo continuo para la mejoría de los resultados pediátricos en países en vía de desarrollo. MÉTODOS: Se presentan siete casos pediátricos de manejo endovascular del tracto de salida derecho; tres de ellos sometidos a valvuloplastia quirúrgica con persistencia de la estenosis pulmonar, por lo cual se decidió inserción percutánea de una válvula pulmonar (IVPP) transcatéter con válvula Melody utilizando la técnica valve-in-valve, con lo que se consiguió una resolución del 100% de la estenosis y no se presentó ningún tipo de complicación asociada al procedimiento. RESULTADOS: En cuatro pacientes se logró una implantación exitosa de la válvula por vía percutánea en diferentes cardiopatías congénitas, siendo uno de ellos en tracto nativo; además, destaca el caso de un paciente en quien se realizó fractura intencional de la válvula pulmonar, procedimiento innovador en el manejo endovascular pediátrico en Colombia. CONCLUSIONES: En estos pacientes el procedimiento resultó ser poco invasivo, seguro y efectivo. La técnica IVPP podría ser considerada una opción viable en Colombia (y en otros países en desarrollo) para el manejo de implantes valvulares primarios fallidos o incluso en tractos nativos.


Asunto(s)
Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Niño , Implantación de Prótesis de Válvulas Cardíacas/métodos , Colombia , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/cirugía , Cardiopatías Congénitas/cirugía , Diseño de Prótesis
9.
J Am Heart Assoc ; 13(6): e033239, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38456473

RESUMEN

BACKGROUND: In recent years, self-expanding technology to treat pulmonary regurgitation in the native right ventricular outflow tract became Food and Drug Administration approved in the United States and is now routinely used. The current practice for selection of patients who are candidates for these devices includes screening for "anatomic fit," performed by each of the manufacturing companies. Our study aims to validate the use of virtual reality (VR) as a tool for local physician-led screening of patients. METHODS AND RESULTS: This retrospective study from Children's Hospital Colorado included patients who underwent pulmonary valve replacement and had screening for a Harmony TPV or Alterra Prestent performed between September 2020 and January 2022. The data from the commercial companies' dedicated analysis for self-expanding transcatheter pulmonary valve frames evaluation with perimeter analysis were collected. VR simulation was performed blinded by 2 congenital interventional cardiologists using Elucis VR software and an Oculus Quest 2 headset. Among the 27 evaluated cases, the use of a self-expandable valve was recommended by companies' dedicated analysis in 23 cases (85.2%), by VR assessment in 26 cases (96.3), and finally implanted in 25 cases (92.6%). Regarding the level of agreement, both modalities (manufacturer and VR) were good at screening-in patients who received a self-expanding valve (100% versus 96.1%). When it came to screening-out the patients, VR presented good capacity to accurately classify nonsuitable patients (50% versus 100%). CONCLUSIONS: Our institutional experience with VR transcatheter pulmonary valve implantation planning accurately predicted clinical outcomes. This paves the way for routine use of VR in patient selection for self-expanding valve technologies.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Realidad Virtual , Niño , Humanos , Estados Unidos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Diseño de Prótesis
10.
Curr Probl Cardiol ; 49(6): 102534, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38521294

RESUMEN

The following letter presents an answer of a comment of our work titled "Ross procedure: valve function, clinical outcomes and predictors after 25 years' follow-up," recently published in your journal by Rangwala et al.1 As our colleagues point out, the Ross procedure has excellent survival rates but a significant risk of valve dysfunction and therefore reintervention at follow-up. Although the survival advantage with the Ross procedure appears to be consistent compared with mechanical valve substitutes, this benefit is not as clear compared with biological valve substitutes. However, biological valve substitutes also have significant reintervention rates during follow-up. The different surgical modifications of the Ross procedure have not clearly demonstrated better results in follow-up in terms of autograft reintervention. This procedure can be performed in a medium-volume center with good results as long as adequate patient selection and adequate surgical training are carried out.


Asunto(s)
Válvula Aórtica , Humanos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/cirugía , Válvula Pulmonar/trasplante , Prótesis Valvulares Cardíacas , Estudios de Seguimiento , Bioprótesis , Procedimientos Quirúrgicos Cardíacos/métodos , Reoperación/estadística & datos numéricos , Enfermedades de las Válvulas Cardíacas/cirugía
11.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419402

RESUMEN

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , Catéteres
12.
Catheter Cardiovasc Interv ; 103(4): 587-596, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38341624

RESUMEN

BACKGROUND: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies. METHODS: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers. RESULTS: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow-up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end-diastolic volume: 163.1 (interquartile range, IQR: 152.0-180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6-137.5 mL/m2  after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid-PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation. CONCLUSIONS: Customized valve insertion sites are pivotal in self-expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Adolescente , Adulto Joven , Adulto , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos , Estudios Retrospectivos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Cateterismo Cardíaco
13.
Circ J ; 88(5): 652-662, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38325847

RESUMEN

BACKGROUND: Coronary artery complications (CACs) in patients who undergoing prosthetic pulmonary valve implantation for congenital heart disease can lead to fetal outcomes. However, the incidence of and risk factors for CACs in these patients remain unknown.Methods and Results: A retrospective cohort study was conducted on patients who underwent cardiac computed tomography or invasive coronary angiography after prosthetic pulmonary valve implantation at Seoul National University Hospital from June 1986 to May 2021. Among 341 patients, 25 (7.3%) were identified with CACs, and 2 of them died. Among the patients with CACs, congenital coronary anomalies and an interarterial course of the coronary artery were identified in 11 (44%) and 18 (72%) patients, respectively. Interarterial and intramural courses of the coronary artery were associated with a 4.4- and 10.6-fold increased risk of CACs, respectively. Among patients with tetralogy of Fallot and pulmonary atresia, the aortic root was rotated further clockwise in patients with coronary artery compression compared to those without it (mean [±SD] 128.0±19.9° vs. 113.5±23.7°; P=0.024). The cut-off rotation angle of the aorta for predicting the occurrence of coronary artery compression was 133°. CONCLUSIONS: Perioperative coronary artery evaluation and prevention of CACs are required in patients undergoing prosthetic pulmonary valve implantation, particularly in those with coronary artery anomalies or severe clockwise rotation of the aortic root.


Asunto(s)
Válvula Pulmonar , Humanos , Estudios Retrospectivos , Femenino , Masculino , Factores de Riesgo , Adulto , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cardiopatías Congénitas/cirugía , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía Coronaria , Adolescente , Adulto Joven , Prótesis Valvulares Cardíacas/efectos adversos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/complicaciones , Incidencia , Niño , Persona de Mediana Edad , Tetralogía de Fallot/cirugía
14.
J Cardiothorac Surg ; 19(1): 61, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38321532

RESUMEN

Fallot-type absent pulmonary valve is a rare and complex congenital heart disease. Repair surgery for this condition during the neonatal period has a mortality rate of over 50%. We reported a neonate with Fallot-type absent pulmonary valve and occlusion of the left main bronchus. The patient's pulmonary artery had unusual anatomy of a type that has not previously been reported. This case report outlines a successful treatment strategy for patients with complex congenital heart disease and airway occlusion during the neonatal period and the effect of these unusual anatomical conditions on postoperative outcomes.


Asunto(s)
Atresia Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Recién Nacido , Humanos , Válvula Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Arteria Pulmonar/cirugía , Bronquios
15.
J Cardiovasc Surg (Torino) ; 65(1): 76-78, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38345548

RESUMEN

Pulmonary homograft dysfunction is challenging to treat in patients with a previous Ross procedure, and results in significant morbidity and mortality in case of reoperation. We report the case of a patient with early severe pulmonary homograft stenosis 18 months after a Ross procedure and successful management using transcatheter pulmonary valve replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Válvula Pulmonar/cirugía , Válvula Pulmonar/trasplante , Resultado del Tratamiento , Trasplante Homólogo , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/cirugía , Reoperación , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Estudios de Seguimiento
16.
Echocardiography ; 41(2): e15765, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38341768

RESUMEN

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Asunto(s)
Insuficiencia de la Válvula Pulmonar , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Tensión Longitudinal Global , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Derecha , Estenosis de la Válvula Pulmonar/complicaciones , Estenosis de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/complicaciones , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/cirugía , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/diagnóstico por imagen
17.
J Med Case Rep ; 18(1): 70, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38378619

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation has become an attractive method of dysfunctional right ventricle outflow tract treatment. CASE PRESENTATION: We describe a unique case of a 20-year-old Caucasian male patient with a complex cyanotic heart defect, namely pulmonary atresia, with congenitally corrected transposition of the great arteries and ventricular septal defect after Rastelli-like surgery at the age of 5 years with homograft use. At the age of 20 years, the patient needed percutaneous pulmonary valve implantation owing to homograft dysfunction. Despite unusual course of the coronary arteries, balloon testing in the landing zone of the right ventricle outflow tract excluded potential coronary artery compression. Then, after presentation, a Melody valve was implanted successfully in the pulmonary valve position. The 8-year follow-up was uneventful. CONCLUSION: This is likely the first description of a percutaneous pulmonary valve implantation in such anatomy. Such a procedure is feasible; however, it requires exceptional caution owing to the anomalous coronary arteries course, which can be the reason for their compression.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Transposición de los Grandes Vasos , Humanos , Masculino , Preescolar , Adulto Joven , Adulto , Transposición Congénitamente Corregida de las Grandes Arterias , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/complicaciones , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/cirugía , Resultado del Tratamiento
18.
Khirurgiia (Mosk) ; (2): 32-44, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38344958

RESUMEN

The literature review is devoted to transcatheter pulmonary valve replacement. The authors summarize the indications, clinical data and current capabilities of transcatheter pulmonary valve replacement. The authors also overviewed modern valves for transcatheter pulmonary artery replacement. Effectiveness of transcatheter pulmonary valve implantation has been substantiated. Various studies comparing the outcomes of different valve systems for endovascular implantation were analyzed. The authors concluded the prospects for transcatheter pulmonary valve implantation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Humanos , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Válvula Pulmonar/cirugía , Reimplantación , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 103(3): 455-463, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38204358

RESUMEN

This manuscript describes the feasibility and approach to the assessment and performance of transcatheter pulmonary valve replacement (tPVR) in patients with surgically-created "double-barrel" right ventricular outflow tracts (RVOT). Patients with tetralogy of Fallot may have coronary anomalies which prohibit the performance of traditional tetralogy of Fallot repair. In certain cases, this may necessitate the placement of a right ventricle to pulmonary artery conduit in addition to the native RVOT, which is left in situ, creating so-called "double-barrel" RVOTs. When these patients develop RVOT dysfunction later in life, they would typically be referred for reoperation due to concerns for risk of coronary compression associated with a transcatheter approach. However, whether a transcatheter approach with valve replacement in the native RVOT is feasible or safe is unknown. This was a retrospective review of patients with a surgically created "double-barrel" RVOTs who underwent cardiac catheterization for assessment of tPVR at Boston Children's Hospital. From July 2012 to July 2022, there were four patients with "double-barrel" RVOTs who underwent assessment for tPVR. The age at catheterization ranged between 22 and 39 years. In three out of four patients, coronary compression testing was negative. These three patients had successful tPVR in the native RVOT. At follow up, all three patients were free of greater than mild regurgitation by echocardiogram and had a maximum instantaneous gradient across the RVOT ranging between 20 and 33 mmHg. Performance of tPVR in patients with surgically created "double-barrel" RVOTs is feasible. The safety of this procedure depends crucially on coronary artery assessment at all stages.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Niño , Humanos , Adulto Joven , Adulto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Ventrículos Cardíacos/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía
20.
Pediatr Cardiol ; 45(3): 570-579, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38296854

RESUMEN

Transcatheter pulmonary valve implantation (TPVI) is a surgical alternative for correcting dysfunctional right ventricular outflow tract in previously operated patients. MyVal transcatheter heart valve (THV) (Meril Life Sciences, India), a new transcatheter valve designed for aortic position has recently been reported to be implanted in pulmonary position. Myval transcatheter valve were implanted in patients with stenosed dysfunctional conduits, severe regurgitation from transannular patch or dysfunctional surgical pulmonary valves (Bioprosthesis). Procedural details and post-TPVI follow-up were analysed. Myval TPVI was used in Fifty three patients with median age of 15 years (IQR 12-19.5 years). Almost sixty percent of the patients were male, with a median weight of 50 kg (31-63 kg). Prestenting was used in more than 80 percent of patients (n = 45 patients), while 6 patients had a prior surgical valve implantation. After Myval TPVI implantation, the peak instantaneous gradient across the RVOT decreased from a median of 23.5 mmHg (IQR 10-53 mmHg) pre-procedure to 10 mmHg (IQR 5-16 mmHg) post-procedure. The median fluoroscopy time for the procedure was 35 min (IQR 23.5-44 min). The large sizes-mainly the 29-mm and 32 mm Myval (Navigator, Meril Life Sciences Pvt Ltd, India), were the most used size in 40% (n = 22) of the cases each. The median contrast volume used during the procedure was 247 mL (IQR 120-300 mL). Patients were followed for a median period of 360 days (IQR 164-525 days). At the last clinic follow-up, there was no tricuspid valve regurgitation. Moderate neo-pulmonary valve regurgitation was reported in three cases. Early experience of TPVI with MyVal is encouraging with procedural success in all patients and acceptable mid-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Masculino , Niño , Adolescente , Adulto Joven , Adulto , Femenino , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Diseño de Prótesis , Cateterismo Cardíaco/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA